<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>19000</ErrorNumber>
<ErrorFamily>Power Distribution Board</ErrorFamily>
<ErrorMessage>
PDB: Air Supply Below Threshold
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The firmware detected that the system air supply is below the threshold specified in the NVS sys
sys_pressure_thresh.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check the air hose connected to the machine and ensure that it has sufficient air pressure.
Also check the threshold value specified in NVS sys sys_pressure_thresh.
</text></DescriptionText>
</OperatorAction>
<Cause>
Improperly calibrated pressure sensor. Run cal pressure command.
</Cause>
<Cause>
Low or No air pressure supplied to the machine.
</Cause>
<Cause>
Invalid NVS value sys sys_pressure_thresh.
</Cause>
<Cause>
Faulty pressure sensor.
</Cause>
<Cause>
Leak in hoses and connection between the supply and the pressure sensor.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sys_cfg_spt.xml</LinkAddress><LinkTitle>NVS: sys spt</LinkTitle></Link>
<Link><LinkAddress>../commands/cal_pressure.xml</LinkAddress><LinkTitle>Command: cal pressure</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:49 2008 PST
</Updated>
<Links>
</Links>
</Error>